Configuring the Logic Analysis System
To load configuration and inverse assembler files ? other logic analyzers
To load configuration and inverse assembler files ?
other logic analyzers
If you have an 1660-series, 1670-series, or logic analyzer modules in an
16500B/C mainframe use these procedures to load the configuration file and
inverse assembler.
The first time you set up the analysis probe, make a duplicate copy of the
master disk. For information on duplicating disks, refer to the reference
manual for your logic analyzer.
For logic analyzers that have a hard disk, you might want to create a
directory such as 68040 on the hard drive and copy the contents of the floppy
onto the hard drive. You can then use the hard drive for loading files.
1Insert the floppy disk in the front disk drive of the logic analyzer.
2Go to the Flexible Disk menu.
3Configure the menu to load.
4Use the knob to select the appropriate configuration file.
Choosing the correct configuration file depends on which analyzer you are
using. The configuration files are shown with the logic analyzer connection
tables, and are also in the table on the next page.
5Select the appropriate analyzer on the menu. The 16500 logic
analyzer modules are shown in the Logic Analyzer Configuration
Files table.
6Execute the load operation on the menu to load the file into the logic
analyzer.
The logic analyzer is configured for 68040 or 68060 analysis by loading the
appropriate configuration file. Loading this file also automatically loads the
appropriate inverse assembler.
E2459A MC68040/060 Analysis Probe2-23 |